Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add filters








Language
Year range
1.
Chinese Journal of Ultrasonography ; (12): 608-611, 2016.
Article in Chinese | WPRIM | ID: wpr-502296

ABSTRACT

Objective To compare the diagnostic efficiency of superb microvascular imaging (SMI) and contrast-enhanced ultrasonographic microvascular imaging (MVI) for differentiating breast lesions.Methods One hundred and sixteen patients with 116 breast lesions were first examined by grayscale ultrasound.Then SMI and MVI were performed on all patients.Microvascular architectures of breast lesions were depicted by both methods.The lesions were evaluated based on their microvascular architectures.The diagnostic efficacy of both methods were compared.Results The diagnostic sensitivity,specificity,and accuracy of SMI and MVI were 79.24%,90.48 %,85.35% and 88.68%,87.30%,87.93%,respectively.The areas under the curve of SMI and MVI were 0.888 and 0.926.The diagnostic values of SMI and MVI were not statistically different (P =0.212).Conclusions SMI can detect tiny vessels and depict microvascular architecture of breast lesions as MVI do,which is beneficial for breast tumor differentiation.The diagnostic efficacy of SMI is almost the same as MVI.

2.
Chinese Journal of Ultrasonography ; (12): 328-331, 2012.
Article in Chinese | WPRIM | ID: wpr-418713

ABSTRACT

Objective To explore the application of contrast-enhanced scoring system in the diagnosis of breast tumor.Methods 249 patients with 260 lesions were examined by elastography and contrastenhanced ultrasound before surgery.All the lesions were scored according to the two different methods.Pathological results were made the golden criteria.The diagnosis accuracy of the two methods were compared.Results There were 145 benign and 115 malignant tumors.The diagnosis accuracy,specificity and sensibility of elastography were 85.0%,88.3%,80.1 % respectively.The critical value of contrastenhanced ultrasound was between 3 and 4.The diagnosis accuracy,specificity and sensibility of contrastenhanced ultrasound were 88.9%,87.6%,90.4% respectively.Area under ROC curve of the two methods were 0.901 and 0.910,the difference was not statistically significant.Conclusions Contrast-enhanced ultrasound 5-point scoring system was an initial quantitative criterion for breast tumor diagnosis.The diagnosis accuracy was parallel to that of elastography.

3.
Chinese Journal of Ultrasonography ; (12): 950-952, 2011.
Article in Chinese | WPRIM | ID: wpr-423212

ABSTRACT

Objective To evaluate the diagnostic value of conventional ultrasound and ultrasonic elastography (UE) in differentiating benign and malignant hepatic lesions.Methods One hundred and forty-five patients with 159 hepatic tumors were included in the study.Conventional ultrasound scan and UE were performed on each patient.Pathological results were as the golden standard.The diagnostic performance of the 2 methods were evaluated with receiver operating characteristic (ROC) curves and the interobserver agreements were analysed.Results A better interobserver agreement was achieved in UE (κ =0.325 at conventional ultrasound versus κ =0.782 at UE).The area under ROC curve of conventional ultrasound,ultrasonic elastography and the combination of both methods were 0.76,0.77 and 0.87,respectively.After the combination of the 2 methods,the sensitivity and accuracy could be enhanced significantly ( P <0.05).Conclusions Conventional ultrasound combined with UE may be more helpful in differentiating malignant from benign hepatic tumors.

4.
Chinese Journal of Ultrasonography ; (12): 787-789, 2010.
Article in Chinese | WPRIM | ID: wpr-386678

ABSTRACT

Objective To investigate the value of ultrasonic elastography(UE) in diagnosing breast small masses (diameter≤10 mm). Methods The static sonograms of conventional ultrasound(US) and UE of the 274 breast small lesions which pathologically proved were reviewed. Images were assigned according to the B1-RADS criteria for US. The elastographic images were evaluated using improved 5-scoring system.Pathology was followed up as diagnostic criteria. The diagnostic performance of the 2 methods was evaluated with receiver operating characteristic curve(ROC). Results The areas under the ROC curve of the two modalities were 0. 891 (UE) and 0.742 (BI-RADS), respectively. The difference between them was significant. Conclusions UE is helpful in differentiating between malignant and benign breast small lesions.

5.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 15-16, 2010.
Article in Chinese | WPRIM | ID: wpr-408647

ABSTRACT

Objective To investigate the causes and prevention of postpartum hemorrhage. Methods 84 cases with postpartum hemorrhage were analyzed. Results The main cause of postpartum hemorrhage was involved in poor contraction of uterus; The second cause was concerned with placenta; There was higher rate of postpartum hemorrhage after caesarean section than vaginal delivery. Conclusion It was necessary for preventing postpartum hemorrhage to strengthen antenatalcare, improve labor observe, decrease caesarean section.

6.
Chinese Journal of Ultrasonography ; (12): 514-516, 2009.
Article in Chinese | WPRIM | ID: wpr-394178

ABSTRACT

Objective To explore the value of improved elasticity scores in differentiating malignant and benign breast lesions. Methods A prospective study was done in 394 patients with 508 breast lesions confirmed by pathology and the elastographic images of the lesions were evaluated by using old and improved elasticity scores respectively. Results The elastographic images of the lesions could be evaluated and classified in all patients by improved elasticity scores but could not be evaluated and classified in 82 lesions by old elasticity scores. The accuracy of ultrasonic elastography for diagnosing benign and malignant breast lesions was 88.8% and 78.1%, respectively by old elasticity scores and improved elasticity scores. Conclusions The elastographic images of breast lesions were accurately evaluated by using improved elasticity scores, and the use of improved elasticity scores is helpful to reduce the biopsy which is not necessary.

7.
Chinese Journal of Ultrasonography ; (12): 589-591, 2009.
Article in Chinese | WPRIM | ID: wpr-393554

ABSTRACT

Objective To investigate the diagnostic value of strain ratio for differentiation breast benign and malignant solid lesions. Methods Two hundred and sixty-nine patients with 377 lesions (278 benign, 99 malignant) were included in the study. Ultrasonography found the lesions, then ultrasonic elastography got the strain images. By the strain ratio measure method equipped with the ultrasonic machine, strain ratio of the lesion was calculated. Compared with the pathologic diagnosis, the cut-off point of strain ratio was determined with receiver operating characteristic curve. Results There was significant difference between the strain ratio of benign and malignant lesions( P <0. 05). The cut off point of strain ratio was determined as 3. 08, Youden's index was 0. 88,sensitivity was 97. 38% ,and specificity was 91. 33%. Conclusions Strain ratio could be used to differentiate benign and malignant lesions in breast and would be a new diagnostic standard in future.

SELECTION OF CITATIONS
SEARCH DETAIL